The release of CADtools MicroStation 2.3 brings with it a number of changes to the Arup CAD Standard, particularly in relation to the levels and their associated symbologies.

Should a project be in progress and these changes are not be required, this page gives instructions on how to make the old standard information available.

There are 4 steps to follow (detailed below):

 

1.Check the current project configuration

 

2. Copy the CadSN 2.2 files to the project

 

3. Edit the project PCF

 

4. Ensure you select the appropriate PCF when opening drawings.

 

Check the current project configuration

 

Locate the "Settings" folder for your project. This will typically be in the same location as the "ProjectSettings.txt" file.

 

Browse to the "Settings\CADtools_Ustn\Dgnlib" folder (example shown below). If there are dgblib files in this location, you will need to take care when copying the CadSN 2.2 files to your project, as the presence of these dgnlib files implies that there is already a project configuration. If you are unsure why these files are there, please contact the CADtools Microstation support team for advice by opening a drawing belonging to the project in question, and using the "Email CADtools Support Team" option on the CADtools menu in Microstation.

 

Edit the project PCF

Using the Project Configuration File (PCF)

Once the relevant files have been added to the project CADtools_Ustn folder location, these files need to be activated for use within MicroStation through a Project Configuration File (PCF).

 

If the project does not have a specific PCF defined for it's use, then one will need to be created. Copy the Example_PCF.txt file from P:\Program Files\Oasys\CADtools_Ustn\Common\Columbus\ (shortcut) and save it to P:\Program Files\Oasys\CADtools_Ustn\Projects\ (shortcut). Then rename the new copy in the format jobnumber.pcf, e.g. "123456-00.pcf".

 

(Note: permission for this operation are limited to CAD Manager's, please speak to your local CAD Manager for assitance with this. For London users only, the Project folder location located here: \\global.arup.com\london\Public\CADtools_Ustn\Projects - shortcut).

 

Editing the Project Configuration File (PCF)

Within the relevant PCF file ensure that the following amendments (highlighted in red) are made:

If not already done so, ensure that the PROJECT LOCATION information is updated

 

 

# PROJECT LOCATION

# ---------------------------------------------------------------------------------------------------------------------

# _PROJECT_DRIVE can either be a drive letter or a URL.

# Note: A drive letter is the preferred solution.

# Activate ONLY one of the following lines

# _PROJECT_DRIVE                = //<server name>/JOBS/                                # Drive

_PROJECT_DRIVE                        = J:/                                                # Drive

_PROJECT_PATH                        = 123000/123456-00/                                # Path to root of Project

_PROJECT_PATH_DRGS                = 4 Internal Project Data/4-03 Drawings/        # Path from Project Root to CAD files

_USTN_PROJECTROOT                    = $(_PROJECT_DRIVE)$(_PROJECT_PATH)                # Full path to Project root

_USTN_PROJECTNAME              = 123456-00                                        # Project Name

_USTN_PROJECTDATA                    = $(_USTN_PROJECTROOT)                                # Project ROOT

MS_DEF                                = $(_USTN_PROJECTROOT)$(_PROJECT_PATH_DRGS)        # Root of Project CAD files

 

Next ensure that the PROJECT SETTINGS FOLDERS have been defined as shown below (for a project with the Settings folder in the root of the project):

 

# PROJECT SETTINGS FOLDERS        (I.e. ../Settings/CADtools_USTN/)

# ---------------------------------------------------------------------------------------------------------------------

_PROJECT_SET                        = $(_USTN_PROJECTROOT)Settings/        

_PROJECT_SET_USTN                = $(_PROJECT_SET)CADTOOLS_USTN/

...

_PROJECT_SET_USTN_CELL                = $(_PROJECT_SET_USTN)Cell/

_PROJECT_SET_USTN_DGNLIB        = $(_PROJECT_SET_USTN)DgnLib/

...

 

Now removed the # symbol from the lines of information in the LEVELS section as shown below:

 

# LEVELS                        (Activate if Project DGNlib's are required)

# ---------------------------------------------------------------------------------------------------------------------

MS_LEVEL_LIB_DIR        = $(_PROJECT_SET_USTN_DGNLIB)                                # Directory for DGNLIB files

MS_FILTER_LIB_DIR        = $(_PROJECT_SET_USTN_DGNLIB)                                # Directory for Filter files

 

If the PCF has not already been created for a project, depending on the project setup, activate only one of the following options by removing the # symbol from the start of the line.

 

(Note: In the example below, the "MicroStation XM version - m" has been activated):

 

# (Activate ONE of the following)

# ------------------------------

# MicroStation XM version - m

# -----------------------

%if defined (_VERSION89)                

 MS_DGNLIBLIST = $(_CADTOOLS_COMMON)Dgnlib/TextDims/TextDimStyles_M.DgnLib

 MS_LINFILELIST = $(_CADTOOLS_COMMON_DATA)DwgData/CADtools_m.lin

%endif

# MicroStation v8 version - m

# -----------------------

#%if defined (_VERSION80)        

#        MS_DGNLIBLIST = $(_CADTOOLS_COMMON)Dgnlib/TextDimStyles_M.DgnLib

#%endif

# MicroStation XM version - mm

# -----------------------

#%if defined (_VERSION89)                

#        MS_DGNLIBLIST = $(_CADTOOLS_COMMON)Dgnlib/TextDims/TextDimStyles_mm.DgnLib

#        MS_LINFILELIST = $(_CADTOOLS_COMMON_DATA)DwgData/CADtools_mm.lin

#%endif

# MicroStation v8 version - mm

# -----------------------

#%if defined (_VERSION80)        

#        MS_DGNLIBLIST = $(_CADTOOLS_COMMON)Dgnlib/TextDimStyles_mm.DgnLib

#%endif

 

Once all of the above changes have been made to the PCF, this should be saved (noting the location as detailed above).

 

Ensure you select the appropriate PCF when opening drawings

When opening MicroStation, ensure that the relevant project is selected from the "Project" menu (bottom right corner)of the MicroStation Manager window:

CADtoolsMicroStationManagerDialog

 

 

 